One-stop solution center for pharmaceutical equipment.

    • Model : TT-II
    • Transparency Testing Range : 20~500 mm
    • Transparency Testing Precision : ±5 mm
    • Volume of Glass Tube : 400mL
    • Size(W×D×H)(mm) : 600×200×630
    • Model : BTT-I; BTT-II; TTH-III; TTH-IV
    • Test Range : 0~5mm; 0~30mm
    • Test Accuracy : ±0.01mm
    • Type of Capsule : 00,0,1,2,3,4 type capsule
    • Model : TTLT-I; TTLT-II
    • Number of Sleeve Racks : 3 sets
    • Timing Precision : ±0.5min
    • Temperature Control Range : 20~45ºC
    • Volume of Beaker : 5L (3PCS)
  • It is a pharmaceutical analysis instrument designed for measuring four physical parameters of tablets: hardness, diameter, thickness and weight.
    • Model : THT-50E
    • Hardness : 10-500 N, resolution 0.01 N, accuracy 0.1 N.
    • Diameter : 2-25 mm, resolution 0.01 mm, accuracy 0.1 mm.
    • Thickness : 0.5-15 mm, resolution 0.01 mm, accuracy 0.1 mm.
    • Weight : 1-20000 mg, resolution 1 mg, accuracy 20 mg.
    • Model : THT-III
    • Hardness Test Range : 2-200N; 0.2KG-20KG (Customizable 500N/50KG)
    • Resolution : 0.1N; 0.01KG
    • Hardness Measurement Aaccuracy : Range ±0.5%
    • Tablet Measurement Diameter : 2-40mm
  • The tablet hardness tester allows for advanced settings such as automatic display, locking and troubleshooting.
    • Model : THT-II
    • Hardness Test Range : 2-200N; 0.2KG-20KG (Customizable 500N/50KG)
    • Resolution : 0.1N; 0.01KG
    • Hardness Measurement Aaccuracy : Range ±0.5%
    • Tablet Measurement Diameter : 2-40mm
    • Model : THT-I
    • Hardness Test Range : 2-198N; 0.2KG-20KG
    • Resolution : 0.1N; 0.01KG
    • Hardness Measurement Accuracy Range : ±0.5%
    • Tablet Measurement Diameter : 2-20mm
  • The TFT series is a double drum tablet friability and abrasion resistance tester commonly used to measure the strength of granules, tablets, cores, fertilisers, and more.
    • Model : TFT-I; TFT-II; TFT-III; TFT-IV
    • Number of Cylinder : 2/1
    • Rotating Speed : 20~100 rpm (can be set arbitrarily)
    • Rotating Accuracy : ±1 rpm
    • Cylinder Depth : 39mm
    • Model : TFT-4
    • Dissolving Quantity : 3pcs
    • Temperature Control Range : (20~40)±0.3℃
    • Speed Adjustable Range : (20~200)±2 rpm
    • Timing Range : (1~600)±0.5min
    • Swing of Paddle Rod : ±0.5mm
    • Model : GST-II; GST-III
    • Test Range : 5-1000 Bloomg
    • Test Precision : ±0.3%
    • Resolution : 1g
    • Repeated Measurement Error : ±1 Bloomg
    • Sampling Depth : 1-60mm
    • Model : DSC-F8DA; DSC-F12DA
    • Sampling Channels : 8 / 12
    • Temperature Range : RT-50.0 ℃
    • Maximum Sampling Times : 40 times
    • Number of Dissolution Vessel Positions : 8 / 14
    • Sampling Volume (Refilling Volume) : 1~20 mL
    • Speed Range : 0–400±1 rpm / 400–1000±4% rpm
    • Model : DT-XII; DT-STIII; DT-STVI; DT-STVIII
    • Speed Range : 20~200 rpm; 20~250 rpm
    • Amplitude of Swing of Stirring Paddle ≤0.3mm
    • Rotating Speed Resolution : 1 time/min
    • Temperature Range : Ambient Temperature~+45.0℃
    • Temperature Resolution : 0.1ºC
  • This dissolution tester provides fast, accurate measurements of release rate and total drug volume over time.
    • Model : DT-I; DT-III; DT-VI; DT-VIII; DT-DVI; DT-DVIII; DT-DSVIII
    • Speed Range : 20~200rpm; 20~250rpm
    • Speed Accuracy : ±2rpm; ±1rpm
    • Temperature Range : Ambient Temperature~+45.0℃
    • Temperature Stability : ±0.3℃
  • This disintegration tester is widely used in the pharmaceutical industry and drug development field.
    • Model : DTLT-3GS
    • Number of Hanging Baskets : 3
    • Lifting Distance : 55±1 mm
    • Upgrade Frequency : 31±1 times/minute
    • Water Bath Temperature : RT ~45 ℃
    • Temperature Resolution : 0.01 ℃
  • It enables reliable measurement of insoluble particles in intravenous injections, pharmaceutical packaging materials, anesthesia equipment, biological products, eye drops, etc.
    • Model: IPC-8AS
    • Test Range: 1-700 μm
    • Minimum Injection Volume: ≥ 0.1 mL
    • Counting Range: 0-9,999,999 particles
    • Detectable Particle Concentration: 0-20,000 particles/mL
    • Stirring Speed: 0-2000 rpm
  • With advanced automated control system and easy operation, this disintegration time limit tester is widely used in pharmaceutical industry and drug discovery.
    • Model : DTLT-BI
    • Disintegration Basket Material : Stainless steel tube
    • Disintegration Basket Round-trip Frequency : 30 times/min
    • Disintegration Basket Moving Distance Up and Down : 10mm±1mm
    • Temperature Control Accuracy : ≤±0.3℃

Title

CONTACT INFO

No. 7000 Jingshi Road, Jinan City, Shandong Province, China

Phone: +86-531-82893797

Go to Top