- Model : LTC-1020; LTC-1040; LTC-1004
- Lift Head : 4/ 4/ 5.6 m
- Compressor : 1/ 1.5/ 8 P
- Refrigerant : R22/ R404/ R404
- Liquid Storage Capacity : 10/ 10/ 100 L
- Bath Opening Diameter : 260/ 260/ 510 mm
- Circulating Pump Flow Rate : 7/ 7/ 60 L/min
- Temperature Range : -20 ℃–RT/ -40 ℃–RT/ -40 ℃–RT
-
Designed to efficiently circulate coolant in systems requiring precise temperature control at low temperatures, compatible with rotary evaporators, vacuum freeze drying oven, etc. -
Designed to efficiently circulate coolant in systems requiring precise temperature control at low temperatures, compatible with rotary evaporators, vacuum freeze drying oven, etc.- Model: LTC-2010; LTC-2020; LTC-2040
- Lift Head : 8 m
- Compressor : 2/ 3 P
- Refrigerant : R22/ R404
- Liquid Storage Capacity : 20 L
- Bath Opening Diameter : 300 mm
- Circulating Pump Flow Rate : 17 L/min
- Temperature Range : -10 ℃–RT/ -20 ℃–RT/ -40 ℃–RT
-
Designed to efficiently circulate coolant in systems requiring precise temperature control at low temperatures, compatible with rotary evaporators, vacuum freeze drying oven, etc.- Model : LTC-4004
- Cycle Mode : Closed cycle
- Lift Head : 2.7/3.4 m (50/60 Hz)
- Maximum Flow : 16/19 L/min (50/60 Hz)
- Temperature Usage Range : -20 ℃–RT
- Condition Liquid Temperature RT 20 ℃
- Temperature Sensor : PT100 thermistor
-
Designed to efficiently circulate coolant in systems requiring precise temperature control at low temperatures, compatible with rotary evaporators, vacuum freeze drying oven, etc.- Model : LTC-5020; LTC-5030; LTC-5040
- Lift Head : 4.6 m
- Compressor : 4P/ 5P/ 7P
- Refrigerant : R404/ R22
- Liquid Storage Capacity : 50 L
- Bath Opening Diameter : 410 mm
- Circulating Pump Flow Rate : 23 L/min
- Temperature Range : -20 ℃–RT/ -30 ℃–RT/ -40 ℃–RT
-
It suitable for companies to conduct accelerated, long-term, high humidity, and strong light exposure tests.- Model : MSTC-250L; MSTC-300L; MSTC-400L; MSTC-500L
- Capacity : 250L; 300L; 400L; 500L
- Convection Method : Forced convection
- Temperature Range : 0~65°C
- Temperature Uniformity : ±2°C
- Temperature Fluctuation : ±0.5°C
-
The outer shell of the microbial air sampler is made of anodized aluminum and features 397 microholes, which effectively reduce bacterial overlap and minimise errors in microbial counting.- Model : AMS-IV
- Sampling Flow Rate : 100 L/min±5% (error)
- Sampling Velocity : 0.38 m/s (isokinetic sampling)
- Sampling Volume : 1-9999 L (adjustable)
- Number of Preset Sampling Points : Can preset 100 groups of points
Get Social