- Model : VDC-100
- Capacity : 100L (Double Chamber)
- Heating Type : Electric Heating
- Drying Temperature : 45~65℃
- Drying Time : 1~999min (Adjustable)
Medical Vacuum Drying Cabinet
Warning: call_user_func_array() expects parameter 1 to be a valid callback, function 'wpb_pcf_contact_form_button' not found or invalid function name in /www/wwwroot/www.scitekuae.com/wp-includes/class-wp-hook.php on line 341
Medical Vacuum Drying Cabinet Feature:
- 7-inch Touch Screen
Displays temperature, pressure, drying time, and stage. - Double Doors
Interlocked front/back doors ensure sealed separation of clean and contaminated areas. - Observation Window
Tempered double-glass with LED lighting for clear drying chamber visibility. - Air Replacement
Automatic ventilation with customizable intervals and frequency. - Data Traceability
Equipped with traceable industrial switches and grid interface.
Medical Vacuum Drying Cabinet Specifications:
| Model | VDC-100 |
| Capacity | 100L (Double Chamber) |
| Internal Size (W×D×H) | 320x220x720mm |
| External Size (W×D×H) | 880x530x1665mm |
| Door | Vertical manual door, double door (front and back), with glass viewing window |
| Display | 7 inch touch screen |
| Working Mode | Chamber a mode, chamber B mode, double chamber mode (A and B)(Each mode has 5 fixed time modes and 6 DIY modes) |
| Alarm | High temperature alarm of drying chamber; |
| Low temperature alarm of drying chamber; | |
| Low pressure alarm of drying chamber; | |
| Low evacuation rate alarm; | |
| Safety Protection | Over voltage protection of power supply; Over temperature protection of drying chamber; Anti-pinch hand function. |
| Heating Type | Electric heating |
| Drying Temperature | 45~65℃ |
| Drying Time | 1~999min, adjustable |
| Drying Chamber Leakage Rate | ≤5Pa/s (Leakage rate was determined under the conditions of no-load, constant temperature of drying chamber, test pressure of 3kPa and test time of 1h.) |
| Ambient Temperature | 5~35℃ |
| Ambient Humidity | Max.relative humidity is 80%, when ambient temperature<31℃; Max.relative humidity is 67%, when ambient temperature is 35℃. |
| Air Filter | ≥99.5% efficiency at 0.3µm |
| Working Pressure | 3kPa |
| Max. Pressure Resistance | 1kPa |
| Vacuum Rate | Vacuum time ≤ 1min, from atmospheric pressure to 3kPa |
| Material | Internal: Aluminium alloy, thickness is 16mm |
| External: 304 Stainless steel, with a whole piece of soundproofing cotton. | |
| Tray | Chamber A: 2pcs trays |
| Chamber B: 2pcs trays | |
| Total 4pcs, 304 stainless steel | |
| Standard | Printer, trays, temperature sensor |
| Consumption | 3.3kW |
| Power Supply | AC220V, 50Hz |
| Shipping Size(W×D×H) | 1070x680x1820mm |
| Gross Weight | 318kg |
WHY SCITEK
- 36 Months Limited Warranty
- CE & FDA Standards
- 1-2 Days Handling and 7-30 Days Shipping