Hydrogen Peroxide Low Temperature Plasma Sterilization Technical Applications:
Low-temperature hydrogen peroxide plasma sterilizers are widely employed for the terminal sterilization of heat-sensitive medical devices, as well as dental handpieces, laboratory analyzers, pharmaceutical packaging components, veterinary surgical tools, and precision aesthetic devices. This technology delivers validated, residue-free microbial inactivation while maintaining the structural integrity and functional performance of delicate polymers, optics, and electronic components.
Hydrogen Peroxide Low Temperature Plasma Sterilization Technical Features:
- Low-temperature sterilization ensures the complete inactivation of microorganisms while preserving the structural integrity and functional fidelity of thermolabile instruments and components.
- Eliminating the need for toxic chemical residues, hazardous by-products, or environmental emissions, thereby fulfilling stringent green manufacturing and sustainability criteria.
- Sterilization efficacy is consistently maintained through precise, real-time control of chamber temperature and hydrogen peroxide concentration, ensuring optimal sporicidal activity across all cycle phases.
- The rectangular sterilization chamber is engineered to maximize volumetric utilization
- Operational safety is reinforced by an electromechanically actuated lift door that physically prevents door opening during pressurized or active sterilization phases.
- Human-centered operation is enabled by an embedded intelligent control processor featuring a graphical touchscreen interface, programmable cycle templates, and one-touch initiation of validated protocols.
- Critical subsystems are sourced from certified industrial-grade suppliers, ensuring long-term reliability.
- The optimized cycle architecture achieves rapid microbial kill while minimizing energy consumption, consumable usage, and labor input—delivering measurable reductions in both operational time and total cost of ownership.
- A sterile-grade, hydrophobic 0.22 µm air inlet filter prevents microbial ingress during vacuum break and post-cycle air admission, safeguarding sterility assurance throughout the entire process sequence.
- Integrated USB data logging provides encrypted, tamper-evident storage of full-cycle parameters.
Low Temp H₂O₂ Plasma Sterilizer Specifications:
| Model |
ST-HT60P |
ST-HT100P |
ST-HT130P |
ST-HT220P |
| Capacity |
60L |
108L |
135L |
192L |
| Door Type |
Manual door |
Automatic door vertical |
| Heating Method |
Electric heating |
| Working Temperature |
45~60℃ |
| Select Sterilizer |
58%-60% hydrogen peroxide (H2O2) |
| Sterilization Time |
35~55minutes |
| Total Cycle Time |
Short cycle 30 minutes, long cycle 50 minutes, lumen cycle 60 minutes |
| Installation Environment |
10-40℃ |
| Temperature Display |
LCD touch screen |
| Max Anti-stree Value |
10pa |
| Operation Height |
≤160cm |
| Power Supply |
AC220/110V, 50/60Hz |
| Consumption |
2.6KW |
3.5KW |
4.2KW |
4.8KW |
| Internal Size(WxDxH)(mm) |
610x350x320 |
700x420x360 |
750x440x400 |
820x510x460 |
| External Size(WxDxH)(mm) |
750x630x1495 |
1120x790x1770 |
| Shipping Size(WxDxH)(mm) |
820x750x1615 |
1300x950x1950 |
| N.W./G.W.(kg) |
185/210 |
265/320 |
272/325 |
305/360 |
Get Social