| Test Speed |
Constant 200 tests/hour |
| Test Principle |
Absorbance photometry, immunoturbidimetric |
| Test Methodology |
End-point, Fixed-time, Kinetic, Single/Double Reagent Chemistry |
| Calibration Type |
Linear/nonlinear multi-points calibration |
| Calibration Model |
Single point, Two point, Multiple point, Logitlog, Segment line, Exponential 5p, Polynomial, Poly4, Spline, Logistic |
| Sample Volume |
1.6–50 µL, 0.1 µL step |
| Sample Dilution |
Automatic/manual pre-dilution, with dilution ratio up to 1:100 |
| Sample Tray |
40 sample positions |
| Reagent Volume |
10–300 µL, 0.1 µL step |
| Reagent Tray |
Internal barcode reader, 40 positions for reagents,reagent tray in 24 hour refrigerated compartment (2–8 ℃) |
Internal barcode reader, 40 positions for reagents, reagent tray in 24 hour refrigerated compartment (2–8 ℃);
Water-cooled mode, compatible with Hitachi 7170 reagent bottles; |
| Reagent/Sample Probe |
Liquid level detection, vertical collision protection, inventory checking |
| Probe Cleaning |
Automatic washing for interior & exterior/carry over < 0.1% |
| Reaction tray |
60 reusable cuvettes |
| Reaction volume |
120–300 µL |
| Reaction time |
10 minutes |
| Reaction temperature |
37±0.1 ℃ |
| Optical length of cuvette |
5 mm |
| Mixing Unit |
Independent mixing bar |
| Cuvette Washing |
Automatic 7-step washing washing system |
8-stage, dual-step automatic rinsing;
Separate collection of high- and low-concentration waste liquids;
Automatic cuvette drying;
Standard configuration includes an automatic dilution function for high-concentration cleaning solutions; |
| Optical System |
Photometry system: rear spectrophotometry |
| Light source: halogen-tungsten lamp (import) |
| Wavelength: 340–700 nm, 9 wavelengths (340, 405, 450, 510, 546, 578, 620, 660, 700 nm), precision ±1.5 nm |
| Absorbance range: 0–3.0 Abs |
| Resolution: 0.0001 Abs/Automatic dilution and re-test when ABS and Linear out of range |
| Control Rule |
One key calibrator import function westgard multi-rule |
| Analysis Method |
End-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard etc, open to various reagents. |
| Operation system |
Windows 7 or above |
| Input |
RS-232 interface/computer |
| Output |
Multi-format printout |
| Interface |
RS-232 |
| Temperature |
10–35 ℃ |
| Humidity |
≤90%, no dew |
| Power Supply |
110 /220 V, 350 W |
| Lower Water Consumption |
5 L/H |
| Size (W×D×H)(mm) |
590×420×330 |
640×440×420 |
| Packing Dimensions (W×D×H)(mm) |
650×480×580 |
880×550×600 |
| N.W/G.W (kg) |
36/40 |
42/60 |