Fully Automatic Dissolution Sampling And Collection System

  • Model : DSC-F8DA; DSC-F12DA
  • Sampling Channels : 8 / 12
  • Temperature Range : RT-50.0 ℃
  • Maximum Sampling Times : 40 times
  • Number of Dissolution Vessel Positions : 8 / 14
  • Sampling Volume (Refilling Volume) : 1~20 mL
  • Speed Range : 0–400±1 rpm / 400–1000±4% rpm

Share the product


Warning: call_user_func_array() expects parameter 1 to be a valid callback, function 'wpb_pcf_contact_form_button' not found or invalid function name in /www/wwwroot/www.scitekuae.com/wp-includes/class-wp-hook.php on line 341

Feature:

  1. Integrated computer OS, smartphone-style icon interface for intuitive operation.
  2. 14-inch LCD all-in-one touchscreen, flexible extension and adjustable positioning.
  3. Four-level user authority management (Super Admin, Admin, Technician, Visitor) for structured access control.
  4. PEEK automatic sampling needle, corrosion-resistant, no adsorption, lifetime durability.
  5. 316L stainless steel paddle and basket, optional PTFE-coated paddle available.
  6. Automatic synchronous dosing device for simultaneous media addition in dissolution tests.
  7. 14-cup / 12-paddle dual-row system (DSC-F12DA), automatic sampling of up to 12 vessels with blank and standard compliance.
  8. Dual speed modes (synchronous & step), optional dual motors for zonal speed control.
  9. 8-cup / 8-paddle dual-row system (DSC-F8DA), automatic simultaneous sampling of up to 8 vessels, supporting blank and standard controls.

Specification:

Model DSC-F8DA DSC-F12DA
Dissolution System
Number of Dissolution Vessel Positions 8 14
Speed Range 0–400 ± 1 rpm / 400–1000 ± 4% rpm
Temperature Range RT-50.0 ℃
Temperature Stability ≤±0.1 ℃
Paddle Radial Run-Out ≤0.5 mm
Basket Radial Run-Out ≤0.8 mm
Deviation Between Rotating Rod and Dissolution Cup Axis ≤1.0 mm
Power Supply AC 220 V±10%, 50 Hz, 1800 W
Sampling System
Sampling Channels 8 12
Maximum Sampling Times 40 times
Sampling Volume (Refilling Volume) 1–20 mL
Minimum Sampling Interval 1 minute for the first time, 2 to 5 minutes for the rest

 (depending on the sampling volume and whether fluid is replenished)

Maximum Working Time 1 to 100,000 minutes (69 days)
Sampling Accuracy ≤±1 % (average value of each channel for 5 mL sampling volume)
Sampling Filtration Cycle <30 s (fully in line with the requirements of the Chinese Pharmacopoeia)
Dimensions (W×D×H)(mm) 550×900×810 600×1400×830
620×550×536 620×550×536
N.W. (kg) 80/60 150/60

标题

CONTACT INFO

No. 7000 Jingshi Road, Jinan City, Shandong Province, China

座机: +86-531-82893797